ATX TC-400R2 400 (2x400) , EPS12V, PS2x2 ( 218.6175174)

: 11661 .

ATX 2x400W TC-400R2 REDUNDANT
Input
AC input:100 to 132 or 198 to 264VAC, user selectable 50 to 60Hz
Maximum inrush current: 40A for 110VAC cold start; 20A for 220VAC cold start
Output: output 1/output 2/output 3/output 4/output 5
Voltage: +5 / +12 / -5 / -12 / 3.3VDC
Maximum load: 40 / 15 / 0.5 / 0.8 / 14A
Minimum load: 10 / 6 / 0.1 / 0.1 / 0.3A (output 1 + output 5: 200W)
Ripple: 50 / 120 / 50 / 120 / 40mV
Ripple/noise: 100 / 150 / 100 / 240 / 40mV
Line regulation: +/-1%
Load regulation: +/-5% / +/-6% / +/-10% / +/-10% / +/-5%
Cross regulation: +/-5% / +/-8% / +/-10% / +/-10% / +/-5%
Remote on/off control: +1.2A SB DC output 750mA
When PS-on is pulled to TTL low, the DC output is to be enabled
When PS-off is pulled to TTL high, the DC output is to be disabled